This insert is made from premium materials on the inside and outside that will put you at the heart of a heating experience for many years to come. These materials include cast iron doors, quiet blowers for greater longevity, high-density bricks, and a stainless steel heat shield added to the C-Cast firestop. Learn about the various choices available to personalize the appearance of your appliance, which come in brushed nickel or black plating: faceplates, door overlays, and faceplate trims.
Specification
APPLIANCE PERFORMANCE (1)
Fuel type : |
Dry cordwood (16" recommended) |
Recommended heating area-ft² : ()
|
500 - 1,800 |
Overall firebox volume-ft³ : |
1.86 |
EPA loading volume-ft³ : |
1.44 |
Maximum burn time : ()
|
7 h |
Maximum heat output-dry cordwood : (2)
|
65,000 BTU/h (19 kW) |
Overall heat output rate < : (2) (3)
|
9,800 BTU/h (2.87 kW) to 52,200 BTU/h (15.3 kW) |
Average overall efficiency (dry cordwood) : (3)
|
68 % (HHV) (4)
|
73 % (LHV) (5)
|
Optimum overall efficiency : (6) (7)
|
76 % |
Optimum heat transfer efficiency : (8)
|
75 % |
Average particulate emissions rate : (9)
|
2.4 g/h |
Average CO : (10)
|
103 g/h |
(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(3) As measured per CSA B415.1-10 stack loss method.
(4) Higher Heating Value of the fuel.
(5) Lower Heating Value of the fuel.
(6) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(7) Optimum overall efficiency at a specific burn rate (LHV).
(8) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(9) This appliance is officially tested and certified by an independent agency.
(10) Carbon monoxyde.
GENERAL FEATURES
Combustion technology |
Non-catalytic |
High-efficiency certified appliance |
Yes, EPA 2020 approved |
Maximum log length |
18" |
Log positioning |
Loading over width |
Chimney diameter |
6" |
Flue outlet diameter |
6" |
Type of chimney |
Liner - ULC-S635, CAN/ULC-S640, UL1777 |
Minimum chimney height (feet) |
15' |
Baffle type |
C-Cast or equivalent |
Approved for a mobile home installation |
No |
Shipping Weight |
361 lb (164 kg) |
Door type |
Single, glass with cast iron frame |
Glass type |
Ceramic glass |
Glass surface – dimensions (Width X Height) |
15 3/4" x 9 3/8" |
Glass air-wash system |
Yes |
Premium quality blower included (CFM) |
144 |
Overall dimension (Height) |
21 1/4" |
Overall dimension (Width) |
27 1/8" |
Overall dimension (Depth) |
22 3/8" |
Door opening – dimension (Height) |
8 3/4" |
Door opening - dimension (Width) |
17 1/4'' |
Firebox – dimension (Height) |
11 7/8" |
Firebox – dimension (Width) |
19 5/8" |
Firebox – dimension (Depth) |
13 1/2" |
Firebox lined with refractory bricks for better heat distribution |
Yes |
Stainless-steel secondary-air system improving gas combustion |
Yes |
Adjustable threaded legs |
Yes |
Steel thickness – body |
3/16" |
Steel thickness – top |
5/16" |
Fireplace opening – minimum (Height) |
21 1/2" |
Fireplace opening – minimum (Width) |
27 1/2" |
Fireplace opening – minimum (Depth) |
12 7/8" |
USA standard (emissions) |
EPA |
Canadian Standard (emissions) |
CSA B415.1-10 |
USA standard (safety) |
UL 1482, UL 737 |
Canadian standard (safety) |
ULC S628 |
Tested and listed as per applicable standards |
By an accredited laboratory (CAN/USA) |
Warranty |
Limited lifetime |
Minimum clearances to combustibles* (Data expressed in inches. 1 inch = 25.4 mm)
|
|
Canada |
United-States |
Clearance – top (measured from the platform on which the appliance is installed)** |
84" |
84" |
Clearance – combustible side mantle to unit |
9" |
9" |
Clearance – combustible top mantle to unit |
27" |
27" |
Clearance – combustible side wall to unit |
16" |
16" |
Clearance – minimum floor protection in front of the appliance |
18" |
16" |
Clearance - from the top of the unit to the shelf |
27" |
|
Clearance – from the top of the insert to the shelf |
|
27" |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
|
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
|
User Manual
GUIDES
Wood insert manual | Safety notifications & general information
(PDF - 2.4 Mo)Osburn 1700 wood insert installation & operation requirements
(PDF - 7.2 Mo)Osburn 1700 dimensions
(PDF - 0.6 Mo)
PLANS & CAD
2D Diagrams
(DWG - 0.3 Mo)2D Diagrams
(DXF - 1.1 Mo)